GAUGE: Fuel Multi Tank - Analogue
Gauge v2.5.001 - Current Version 12th Feb 2024

Features:
12 Fuel Gauges in one
 
1) Left tanks (Main, Aux & Tip)
2) Right tanks (Main, Aux & Tip)
3) Centre tanks (1, 2 & 3)
4) External Tanks (1 & 2)
5) Selected Tank % (Default % of All)
6) Optional Glass Reflections
7) Toggle Blanking Plates [S6]
8) Brightness Control (Physical FIP)

Aircraft Compatibility:
Simulator: Fully Compatible
3rd Party: Not Tested
Please report any 3rd Party incompatibility via our discord channel

Buttons & Dials Summary:
[S6] Toggle Blanking Plates:
[L Dial] Menu Value Down/Up:
[R Dial] Menu Left/Right:

About Fuel Multi Tank - Analogue:
When Activating Buttons the Left and Centre gauges move over and the External and Selected tank gauges will no longer be visible.
 
Yellow Needles are active/available tanks
Grey Needles are not applicable tanks for the current aircraft

The Main Gauge:
The main gauge window will either show 12 tank outputs or 9 depending if the side buttons have been turned on.
 
The gauge show fuel quantity only for tanks that are valid for the loaded aircraft. Invalid tanks will show no output and a grey needle unless blanking plates has been turned on.
 
Monitors all 12 SIMCONNECT tanks:
     Left tanks (Main, Aux & Tip)
     Right tanks (Main, Aux & Tip)
     Centre tanks (1, 2 & 3)
     External Tanks (1 & 2)
     Selected Tank % (Default % of All)

The Sidebar:
When side buttons are turned on only 9 gauges can be displayed in the main gauge window, the External Tanks wont be shown in the main gauge layout.
 
If the blanking plate is used instead of the sidebar, then colour of the plate can now be changed by editing variable [FG_GLOBAL_BLANKING_COLOUR] in SPAD.neXt data monitor.

Buttons & Dials Details:
[S6] Toggle Blanking Plates:
Press to toggle off invalid tanks and replace with a blanking plate instead.
 
[L Dial] Menu value down/up:
When Mini Menu is open use [L Dial] to change the value of the selected menu option.
 
[R Dial] Menu Function Previous/Next:
Used to activate the Mini Menu and scroll between the various menu options.
 
 

The Mini Menu:
Version & Info:
Turn left dial clockwise to turn on and counter clockwise to turn off current version number and other useful links.
 
Side Buttons:
Turn left dial clockwise to turn on and counter clockwise to turn off side buttons.
 
Blanking Plates:
This menu option allows you to turn off invalid tanks and replace with a blanking plate instead. Otherwise Active tanks will show with a Yellow needle and invalid tank will show with a grey needle at "0"
 
Glass Reflection:
Turn left dial clockwise to turn on and counter clockwise to turn off optional glass reflections. This is a global setting so all gauges that have this function will turn on and off.
 
Background Colour:
Left dial will change colour styles to the following
    1) Dark grey panel with dark grey clock face
    2) Dark grey panel with black clock face
    3) Very dark grey panel with black clock face
    4) Black panel with black clock face.
 
Brightness:
Turn left Dial clockwise to increase gauge brightness and counter clockwise to decrease gauge brightness. This will adjust the brightness of all gauges at the same time.
 
 

Variables:
FG_MULTIFUEL_MENU (Session)
     Menu Item Index (0 to 7)
     0 = Menu Closed
     1 = Version & Info
     2 = Side Buttons
     3 = Blanking Plates On/Off
     4 = Glass Reflections
     5 = Background colour
     6 = Brightness control
     7 = Panel Lights Control
 
FG_MULTIFUEL_BUTTONS (Profile)
     Side Buttons (Off = 0, On = 1)
 
FG_MULTIFUEL_LABELS (Profile)
     Side Button Labels (Off = 0, On = 1)
 
FG_MULTIFUEL_INSTRUCTIONS (Session)
     Instructions Page (Off = 0, On = 1)
 
SIMCONNECT Vars Used:
FUEL TANK LEFT MAIN CAPACITY,Gallons
FUEL TANK LEFT MAIN LEVEL,PERCENT
FUEL TANK LEFT AUX CAPACITY,Gallons
FUEL TANK LEFT AUX LEVEL,PERCENT
FUEL TANK LEFT TIP CAPACITY,Gallons
FUEL TANK LEFT TIP LEVEL,PERCENT
FUEL TANK CENTER CAPACITY,Gallons
FUEL TANK CENTER LEVEL,PERCENT
FUEL TANK CENTER2 CAPACITY,Gallons
FUEL TANK CENTER2 LEVEL,PERCENT
FUEL TANK CENTER3 CAPACITY,Gallons
FUEL TANK CENTER3 LEVEL,PERCENT
FUEL TANK EXTERNAL1 CAPACITY,Gallons
FUEL TANK EXTERNAL1 LEVEL,PERCENT
FUEL TANK EXTERNAL2 CAPACITY,Gallons
FUEL TANK EXTERNAL2 LEVEL,PERCENT
FUEL SELECTED QUANTITY PERCENT,Percent
FUEL TANK RIGHT MAIN CAPACITY,Gallons
FUEL TANK RIGHT MAIN LEVEL,PERCENT
FUEL TANK RIGHT AUX CAPACITY,Gallons
FUEL TANK RIGHT AUX LEVEL,PERCENT
FUEL TANK RIGHT TIP CAPACITY,Gallons
FUEL TANK RIGHT TIP LEVEL,PERCENT
FUEL SELECTED QUANTITY PERCENT,Gallons
 
fipgauges.com GLOBAL VARIABLES:
(not all vars used in every gauge)
 
FG_GLOBAL_DIAL_SPEED (Session)
     Variable used for dial acceleration (Off = 0, On = 1)
 
FG_GLOBAL_GAUGE_BRIGHTNESS (Profile)
     Brightness value of physical FIP's. Affects all physical gauges (20-250)
 
FG_GLOBAL_GAUGE_BRIGHTNESS_MODE (Profile)
     Variable used when editing Global or individual Brightness (0-1)
     0 - Global Brightness
     1 - Inedividual Brightness
FG_GLOBAL_BLANKING_COLOUR (Profile)
     Text Variable used to set blanking plate colour
 
FG_GLOBAL_GLASS (Profile)
     Glass Reflection (Off = 0, On = 1)
 
FG_GLOBAL_HIDE_MENU_LED (Profile)
     Toggle visibility of Mini Menu LED (0 = On, 1 = Off)
 
FG_GLOBAL_JET_COLOUR (Profile)
     Background Colour (0 to 3)
     1 = Grey panel with grey gauge face
     2 = Blue grey panel with grey gauge face
     3 = Dark grey panel with black gauge face
     4 = Dark blue panel with black gauge face.  
 
FG_GLOBAL_JET_BACKGROUND_COLOUR (Profile)
     Background Colour (Black = 0, Blue = 1 )
 
FG_GLOBAL_MIN_VOLTAGE (Profile)
     Minimum voltage before gauge electronics turns off (-1 to 150)
     -1 = Disabled
     0 - 150 = Off Voltage Level
 
FG_GLOBAL_MIN_VOLTAGE_CACHE (Profile)
     Internal Variable - Used to store off voltage value - do not edit
  
FG_GLOBAL_PANEL_LIGHTS (Profile)
     Night Lit Mode (Off = 0, On = 1)
 
FG_GLOBAL_PRESSURE (Profile)
     Shared variable for switching inHg and MB (0 to 1)
     0 = inHg
     1 = Millbars
 
FG_GLOBAL_STYLE (Profile)
  Background Colour (0 to 6)
     0 = Grey
     1 = Black Dial Face
     2 = Darker Gauge & Dial Face
     3 = Black & No Gauge GFX
     4 = Grey - Original Design
     5 = Black Dial Face - Original Design
     6 = Darker Gauge & Dial Face - Original Design
   
FG_GLOBAL_VOLTAGE (Session)
     Internal variable used to read current voltage
 
FG_GLOBAL_BLANKING_COLOUR (Profile)
     Text Variable used to set blanking plate colour

Release Notes:
2.5.001 - Using New Sidebar Button and Labels Code (4 display options now also) - blank sidebar custom colour
2.5.000
     1) SPAD.neXt 0.9.15 Compatibility (Convert "PRESS" to "PRESSSHORT") Fixes short and long press both firing on long press.
     2) Menu system upgraded
     3) New gauge brightness code using SPAD brightness variables.
     4) Can control global or individual gauge brightness in gauge (Profile saved settings)
     5) Better use of button lights
     6) Added Custom Colour for blanking plate - Edit colour index for variable FG_GLOBAL_BLANKING_COLOUR
2.4.002 - SPAD.neXt 0.9.13 Compatibility (Author ID)
2.4.001 - Fixed background style only using first 2 of 7 styles
2.4.000 - New Custom Virtual Power supports ALL aircraft volt variables - See https://fipgauges.com/customfeatures.php
2.3.007 - Virtual Power Warning added to Menu
2.3.005 - Added Panel Lighting control in Mini Menu
2.3.004 - Support for NEW 4 colour hue panel lights.
2.3.003 - Tweaked voltage monitoring to better support MSFS2020. Added Monitoring for Battery Bus2.3.002 - SPAD.neXt 0.9.7.x Variable Scope Compatibility
2.3.001 - Added Brightness Control to Mini Menu
2.3.000 - Panel Lights now controlled by local variable (FG_GLOBAL_PANEL_LIGHTS) 0=Off 1=On
2.2.000 - Added optional blanking plates [S6] toggle
2.1.001 - Resized Text to become compliant with SPAD.neXt scaling changes
2.0.000 - New colour schemes available in mini menu.
1.1.000 - Improved graphics with shadows and transparency, Optional glass reflections.
1.0.000 - Beta/1st Public Release

Please report any bugs or feature requests via our discord channel


Document Published 12/02/2024

Copyright fipgauges.com 12/02/2024